Wide capacity series from 10 kVA to 50 kVA Online UPS system Three-phase, 10 to 50 kVA
This online UPS system continually supplies power without interruption at a constant voltage and constant frequency.
With six models available from 10 kVA to 50 kVA, users can select the best model for their load system.
Parallel operation of UPS systems can be done easily, such as for capacity expansion to match future load increases and for redundant operation to improve reliability.
About a 40% reduction in device mass compared to previous models On-line type UPS Three-phase, 30 to 100 kVA
Utilization of 3-level modules with RB-IGBTs*1 and conventional IGBTs in one package to simplify the circuit configuration as well as miniaturization of filters have reduced the mass of the equipment by about 40% compared with our conventional models.
Our new power conversion technology (featuring new three-level conversion circuits) reduces the switching losses of the IGBT elements. Additionally, reducing the harmonic components in the PWM waveform output from the inverter by half compared with our conventional products reduces filter losses and achieves a best-in-class equipment efficiency of 95%*2.
| Item | Fuji Electric conventional UPS | 7100MX Series | Remark |
|---|---|---|---|
| Output | 100kVA 80kW | 100kVA 80kW | |
| Efficiency | 90% | 95% | Maximum equipment efficiency |
| Loss | 8.9kW | 4.2kW | |
| Annual energy losses | 77,960 kWh | 36.790 kWh | = Loss kW x 24 hr. x 365 days |
| Annual loss electricity charges | 1,170,000 yen | 550,000 yen | Electricity charges: calculated at 15 yen per kWh |
| CO2 emissions from annual energy | about 29.6 t | about 14.0 t | 0.38 kg - CO2/kWh |
The above table represents approximate calculation values for continuous operation at a 100% load for one year.
An LCD touch panel with character display enables the operation status of the equipment to be checked at a glance and operation guidance, event history and various measurements to be displayed.
The rated input and output voltage can be set within a range of 200 to 220 V. This wide range has been achieved by an addition of 220 V to the conventional rated input and output voltages of 200 V and 210 V. In addition, the input voltage tolerance range is −30% to +10% of the rated voltage and the output voltage is kept constant without requiring battery operation even in power transmission environments that experience large voltage fluctuations. (Note that this performance is dependent upon the load conditions.)
The installation of an optional Web/SNMP card makes it possible to monitor the status of the equipment using a web browser, receive event notifications by e-mail, perform remote maintenance, shut down multiple servers, and monitor the status using SNMP manager software (JEMA-MIB compatible).
A maintenance bypass circuit built into the UPS is available as an option. This built-in maintenance bypass circuit enables higher maintainability with only the UPS equipment.
Supporting the high-level requirements of ICT equipment On-line type UPS Three-phase, three-wire, 100 to 300 kVA
UWith the widespread use of power factor correction (PFC) circuits, power can be supplied effectively to load equipment with high power factors (1.0).
| Item | DX Series* | Fuji Electric conventional UPS * | |
|---|---|---|---|
| Rated load | 1.0 | 0.9 (lag) | |
| Output capacity | 〔kVA〕 | 100 | 100 |
| 〔kW〕 | 100 | 90 | |
| Number of 5 kW servers supported (example) | 20 units | 18 units | |
* This is a comparison between 100 kVA units.
The industry's highest output power [kW] per installation area has been achieved by increasing the output power [kW] in the same installation space required by conventional units. (300 kVA unit)
By means of an efficient arrangement of multiple small cooling fans, power supplied by the UPS can be continued even if one cooling fan stops. This function improves the availability of the system. (When operating in the recommended operating environment.)
This UPS is adaptable to the configuration of high-reliability systems (parallel redundant operation mode, common stand-by operation, etc.), and by applying our own fully independent parallel redundant operation method, which does not have a common control section, parallel redundant operation systems can be constructed. Up to 8 units can be operated in parallel, and large-scale system configurations are supported. In addition, this UPS can be applied to various types of systems such as collective busbar, multiple busbar, common battery and others.
This function gradually shifts the load to the direct feed (bypass) circuit by controlling the inverter output current when manually switching from the inverter supply to direct feed (bypass) power supply such as for maintenance inspections. This function can suppress abrupt load changes to the grid power side and reduce voltage fluctuations.
A large, wide-format 7-inch touch panel is used for operation and display screens. Operation guidance, operation status, and measurements of each part can be checked more easily.
Long-life fans with significantly extended expected service life are available as an optional replacement for standard fans (with expected service life of 5 years *). Use of these long-life fans are an effective means of reducing parts replacement costs.
With the installation of an optional Web/SNMP card, it is possible to monitor the status of the UPS using a web browser, receive event notificatins by email, perform remote maintenance, shut down multiple servers, and monitor the status using SNMP manager software (JEMA-MIB supported).
Falcon 8500 range of Three Phase Online UPS systems are designed and built to function in the critical network and cloud environments maintaining both data security and business continuity. With a 32-bit DSP controlled UPS, the unique modular design and compact footprint comes with variety of special features including true RMS reading of more than 25 parameters, advanced thermal design and monitoring functions as well as inbuilt galvanic isolation.
Fuji Electric Falcon X7 is true online double conversion UPS system with it’s Advance T-Type NPC 3-Level Inverter technology which delivers AC to AC efficiency upto 96.5% to help user to have lowest total operating cost. Falcon X7 delivers rated output power at 0.9 or Unity PF with it’s wide range of operating load power factor spanning 0.5 lag to 0.7 lead which ensure user can operate the system wide range of application.
Fuji Electric Falcon X5 is true online double conversion UPS system coupled with built in galvanic isolation & advance T-Type NPC 3- Level Inverter Technology. It's Efficient & sustainable design delivers the unmatchable efficiency upto 95% in it's class and helps user to have overall optimized total cost of ownership and at the same time delivering maximum uptime & performance.
High-level performance by means of high-speed switching On-line type UPS Three-phase, three-wire, 400 to 1,000 kVA
The UPS 6000D-3 series makes use of new fifth-generation IGBTs that have lower loss and improved high-frequency switching characteristics compared with conventional IGBTs *1, which enables higher reliability and higher performance.
The control unit and monitoring unit are independent, and the monitoring unit uses redundant software and hardware for high reliability.
High reliability is achieved by the use of an integrated configuration of IGBTs, fuses, and drive circuits, and large current panels for the wiring. In addition, the modules use a plug-in tray structure and maintenance is possible from the front side.
Full digitalization using high-performance processors has greatly reduced the number of parts and achieved high reliability.
About a 40% reduction in device mass compared to previous models On-line type UPS Three-phase, three-wire, 500 kVA
The world's highest level of device efficiency at 97%
Support for various high-reliability systems
Compact, lightweight design
New power conversion
High-capacity UPS features high reliability and high functionality On-line type UPS Three-phase, four-wire, 400 to 2500 kVA
High efficiency of 96.5 % achieved with a three-phase, four-wire constant inverter power supply system
High reliability achieved through systemization and our proven track record
Variety of functions achieved through our proven track record
Compact and lightweight design
High-capacity modular UPS adhering to the needs of high-power data centers On-line type UPS Three-phase, three-wire, 1,200 kVA
“HE mode*” continuous commercial power supply system
HE mode compatible type is now available, in addition to hybrid type, similar to conventional products. With the HE mode, when the commercial power supply is normal, the inverter receives it through a bypass power supply circuit to reduce power consumption, achieving a power supply efficiency of 98.5%. When abnormality occurs, the inverter uninterruptedly transfers to the inverter feeding mode while improving the power factor. It further reduces power loss and contributes to the improvement of data center PUE.
Shortens MTTR
Excellent availability provided with an MTTR of approximately 1 hour and an uptime of 99.9991%. This is suitable for use in critical systems
Supports high-reliability systems
We are providing reliable systems that can continuously supply power 24 X 7 with parallel or standby redundancy.
Unparalleled support
In addition to UPS systems, we support all aspects of systems necessary for stable power supply, from the design of electrical facilities to the procurement and manufacture of equipment.
Reduced footprint
The UPS7500WX has a footprint-saving design with a standard module configuration of 3,500 mm wide × 900 mm deep, providing more space for server equipment. Further space savings are achieved by eliminating the need for maintenance space on the back and sides of the panel.
Provision of redundant fans on top
The need for maintenance space on the back and sides is eliminated. This is achieved by drawing in air from the front and releasing it at the top.
Eliminates I/O modules
The I/O modules for connecting main circuit cables during system design are eliminated. This facilitates direct inseries connection of peripheral panels with custom builtin molded-case circuit breakers and transformers. Further UPS system space savings are thus achieved.
Reduces power consumption by about 90% Power regeneration feature (our patented technology)
A simulated load test device (by operating a separate unit) in regenerative mode is presented. This technology can reduce power consumption by about 90%. This eliminates the need to lease, install, or remove load testing devices. Additionally, the cost of load testing by technicians is significantly reduced.
3-phase 4-wire high-capacity UPS
This High-capacity 600 to 1,200-kVA UPS supports increased power consumption per rack with up to four modules in parallel. Both 3-phase 3-wire and 3-phase 4-wire systems are available for the output.
Fuji Electric Falcon X7 is true online double conversion UPS system with it’s Advance T-Type NPC 3-Level Inverter technology which delivers AC to AC efficiency upto 96.5% to help user to have lowest total operating cost. Falcon X7 delivers rated output power at 0.9 or Unity PF with it’s wide range of operating load power factor spanning 0.5 lag to 0.7 lead which ensure user can operate the system wide range of application.